Sr. No. |
Name of the Equipment |
Type/Make |
Qty. |
Accuracy Class |
Application
/use |
|
01 |
Intermediate Transformer |
Make: Aditya
Capacity: 7.5 MVA
Voltage: 433-24 KV in 18 Steps (OFWF cooled) |
01 |
- |
No load loss.
Load loss.
Induced Overvoltage Test.
Voltage Test.
Heat Run Test. |
|
02 |
LT Capacitor Bank |
Make: Savin Elects.
Capacity: 4000 KVAR
Voltage: 440 Volts.
3 Phase, 50 Hz. |
01 Set. |
- |
No load loss.
Load loss.
Induced Test.
Heat Run Test. |
|
03 |
HT Capacitor Bank |
Make: Savin Elects.
Capacity: 3600 KVAR
Voltage: 6.6/11.4/22.8 KV By change of Connections.
3 Phase, 50 Hz. |
01 Set. |
- |
No load loss.
Load loss.
Induced Test.
Heat Run Test. |
|
04 |
Transformer |
Make: Aditya
Capacity: 1000 KVA
Voltage: 22/.433 KV |
01 No. |
- |
For Supply & All Tests. |
|
|
|
|
|
|
[
Ù
Top ] |
|
05 |
Transformer |
Make: Aditya
Capacity: 1000 KVA
Voltage: 3/.400 KV |
01 No. |
- |
Motor Gen. Set Starting. |
|
06 |
Regulating Transformer |
Make: Delta Elect.
Capacity: 1000 Amps.
Voltage: 0-440 V.
ONAN cooled, Motorised. |
01 No. |
- |
All Tests. |
|
07 |
Regulating Transformer |
Make: Automatic Elec.
Capacity: 40 Amps.
Voltage: 0.440 V.
ONAN cooled, Motorised. |
01 No. |
- |
All Tests. |
|
08 |
Regulating Transformer |
Make: Trigana Elec.
Capacity: 40 Amps.
ONAN cooled, Motorised. |
01 No. |
- |
All Tests. |
|
09 |
Regulating Transformer |
Make: Trigana Elec.
Capacity: 4 Amps. |
01 No. |
- |
All Tests. |
|
10 |
High Voltage Flash Testing Transformer |
Make: Aditya
Capacity: 300 KVA
Voltage: 0-300 KV
Current: 1 Amp, 1 Phase. |
01 No. |
- |
Dielectric Test. |
|
|
|
|
|
|
[
Ù
Top ] |
|
11 |
High Voltage Flash Testing Transformer |
Make: SEV Assoc.
Capacity: 0.2 Amp.
Voltage: 0-60 KV, 1 Phase. |
01 No. |
- |
Dielectric Test. |
|
12 |
High Voltage Flash Testing Transformer |
Make: SEV Assoc.
Capacity: 0.1 Amp.
Voltage: 0.5 KV, 1 Phase. |
01 No. |
- |
Dielectric Test. |
|
13 |
Sphere Gaps |
Make: Aditya
500 MM dia. Airgap with peak volt meter. |
01 No. |
- |
Measurement of EH Voltage Dielectric Test. |
|
14 |
Capacitive Divider |
60 PF, 150 KV with peak volt meter |
01 No. |
- |
All Dielectric Test. |
|
|
|
|
|
|
[
Ù
Top ] |
|
15 |
Transformer Ratio Meter |
Make: Eltel
Capacity: 2021/1 Ratio 230 Volts, 1 Phase |
01 No. |
- |
Voltage Ratio Test. |
|
16 |
Transformer Ratio Meter |
Make: SEV Assoc.
Capacity: 300/1 Ratio 230 Volts, 1 Phase |
01 No. |
- |
Voltage Ratio Test. |
|
17 |
Motor Generator Set |
Make: Ganesh Eng.
Capacity: 500 KVA
Frequency: 200 Hz.
Voltage: 440 Volts, 1 Phase |
01 No. |
- |
Induced Over Voltage Test. |
|
18 |
Motor Generator Set |
Make: Kirloskar
Capacity: 40 KVA
Frequency: 150 Hz.
Voltage: 440 Volts with 50 KVA, 440/880 Volts Intermediate Transformers. |
01 No. |
- |
Induced Over Voltage Test. |
|
19 |
Reactor |
Make: Aditya
Voltage: 45 KV Class, 500 to 3500 Ohms. |
01 No. |
- |
Induced Over Voltage Test. |
|
20 |
Manual C & Tan Delta Bridge |
Make: Shivanand
Model: MLS - 11D |
01 No. |
- |
Tan Delta Test. |
|
|
|
|
|
|
[
Ù
Top ] |
|
21 |
Kelvin Bridge |
Make: Toshniwal
Range: up to 1 microohms. |
01 No. |
1% |
Measurement of winding resistance. |
|
22 |
Whestone Bridge |
Make: Toshniwal
Range: up to 1 milliohms. |
01 No. |
1% |
Measurement of winding resistance. |
|
23 |
Digital Resistance Meter |
Make: Prestige Electronics,
Range: up to 1 microohms. |
01 No. |
1% |
Measurement of winding resistance. |
|
24 |
Spot reflecting Galvanometers. |
Make: Toshniwal |
01 No. |
- |
Measurement of winding resistance. |
|
|
|
|
|
|
[
Ù
Top ] |
|
25 |
Oil Test Set |
Make: SEV Assoc.
Range: 1 Ph., 0-6 KV, Motorised |
01 No. |
- |
Break down voltage of oil. |
|
26 |
Oil Test Set |
Make: SEV Assoc.
Range: 1 Ph., 0-100 KV, Motorised |
01 No. |
- |
Break down voltage of oil. |
|
27 |
Multimeter |
Make: Motwani |
01 No. |
1% |
All purpose. |
|
28 |
Digital Multimeter |
Make: MECO |
01 No. |
1% |
All purpose. |
|
29 |
Karl Fisher Titrator |
Make: VEEGO
Model: V/M III |
01 No. |
- |
Measurement of Moisture Content in oil. |
|
30 |
Dielectric Loss & Model: MLS 11 D. |
Make: Shivananda Electronics
Model: MLS 11 D,
Voltage: 230 Volts, 1 Ph. |
01 No. |
1% |
Oil Testing. |
|
31 |
Acidity Test Set |
hemical Type |
01 No. |
- |
Oil Testing. |
|
32 |
Meggar |
Make: UDEYRAJ
Voltage: 5000 Volts, 50000 M.Ohms. Motorised. |
01 No. |
- |
Measurement of Insulation Resistance. |
|
33 |
Meggar |
Make: Shanti
Voltage: 2000 V. 1000 M.Ohms. Hand Operated. |
01 No. |
- |
Measurement of Insulation Resistance. |
|
34 |
|
|
|
|
[
Ù
Top ] |
|
a) |
Potential Transformer |
Make: Test Filed
Range: 3 Ph., 33-22-11 KV/ 110 V.
Burden: 25 VA. |
01 No. |
0.2% |
Voltage & Loss Measurement. |
|
b) |
Potential Transformer |
Make: Test Filed
Range: 3 Ph., 11-6.6-3.3-2.2-1.1 KV/ 110 Volts
Burden: 25 VA. |
01 No. |
0.2% |
Voltage & Loss Measurement. |
|
c) |
Potential Transformer |
Make: Automatic
Range: 3 Ph., 800-600-400/ 110 Volts
Burden: 25 VA. |
01 No. |
0.2% |
Voltage & Loss Measurement. |
|
d) |
Potential Transformer |
Make: Automatic
Range: 1 Ph., 33-22-11/ V3/ 110 V/ V3
Burden: 25 VA. |
03 Nos. |
0.2% |
Voltage & Loss Measurement. |
|
e) |
Potential Transformer |
Make: Automatic
Range: 1 Ph., 11-6.6-3.3-2.2-1.1/ V3/ 110/ V3
Burden: 25 VA. |
03 Nos. |
0.2% |
Voltage & Loss Measurement. |
|
f) |
Current Transformer |
Make: Accurate
Range: 2000-1000-500-250/5 A, 660 Volts. |
04 Nos. |
0.2% |
Current & Loss Measurement. |
|
g) |
Current Transformer |
Make: Accurate
Range: 100-50-25-12.5-5/5 A, 660 Volts. |
04 Nos. |
0.2% |
Current & Loss Measurement. |
|
h) |
Current Transformer |
Make: Automatic
Range: 120-60-30-15-10-5/5 A, 660 Volts. |
03 Nos. |
0.2% |
Current & Loss Measurement. |
|
35 |
Tans Measurement Kit |
Make: Shivananda |
|
|
Measuring Tans of bushing/ Trf. |
|
36 |
1600 amp. Auto Transformers |
0-440 Volts |
|
|
Measurement of Load Loss/ No Load Loss. |
|
37 |
MEASURING INSTURMENTS |
|
|
|
[
Ù
Top ] |
|
a) |
Wattmeter |
Make: Automatic
Type: Low PF, Dynamometer
Voltage: 150-300-600 V,
1/5 Amp. |
03 Nos. |
0.5% |
Measurement of No Load/ Load Losses. |
|
b) |
Wattmeter |
Make: Automatic
Type: Low PF, Dynamometer
Voltage: 150-300-600 V,
1 Amp. |
02 Nos. |
0.5% |
Measurement of No Load/ Load Losses. |
|
c) |
Wattmeter |
Make: Automatic
Type: Low PF, Dynamometer
Voltage: 150-300-600 V,
2 Amp. |
02 Nos. |
0.5% |
Measurement of No Load/ Load Losses. |
|
d) |
Ammeter |
Make: Automatic
Type: Low PF, Dynamometer
Voltage: 0-1-5 Amp. 660 Volts |
03 Nos. |
0.5% |
Measurement of No Load/ Load Losses. |
|
e) |
Ammeter |
Make: Automatic
Type: Low PF, Dynamometer
Voltage: 0-1-5 Amp. 660 Volts |
03 Nos. |
0.5% |
Measurement of No Load/ Load Losses. |
|
f) |
Voltmeter |
Make: Automatic
Type: Low PF, Dynamometer
Range: 150-300-600 V. |
03 Nos. |
0.5% |
Measurement of No Load/ Load Losses. |
|
g) |
Voltmeter |
Make: Accurate
Type: Low PF, Dynamometer
Range: 0-150 V. |
03 Nos. |
0.5% |
Measurement of No Load/ Load Losses. |
|
h) |
Voltmeter |
Make: Accurate
Type: Moving Iron,
Range: 0-150 V. |
03 Nos. |
0.5% |
Measurement of No Load/ Load Losses. |
|
i) |
Voltmeter |
Make: Accurate
Type: Rectifier
Range: 0-150 V. True RMS. |
03 Nos. |
0.5% |
Measurement of No Load/ Load Losses. |